架构调整,质量计算模型分块包装
This commit is contained in:
1 parent
5709ed5f71
commit
c5b85f5354
3 files changed
+234
-178
No files matched your search
@@ -0,0 +1,196 @@
|
||||
# -*- coding: utf-8 -*-
|
||||
"""Mass-estimation models for Brayton cycle components."""
|
||||
|
||||
import math
|
||||
|
||||
|
||||
def calculate_turbine_mass(component, Pe=None, A=0.5, **kwargs):
|
||||
"""Estimate turbine/TAC mass with the empirical TAC formula.
|
||||
|
||||
Formula from the provided reference:
|
||||
M = A * sqrt(0.5*pi*(30.522*ln(Pe) - 5.7178))
|
||||
|
||||
If Pe is not supplied, the current turbine specific work ``Wt`` is used
|
||||
directly as Pe without unit conversion.
|
||||
"""
|
||||
if not 0.4 <= A <= 0.8:
|
||||
raise ValueError("A should be within the recommended range 0.4-0.8")
|
||||
|
||||
if Pe is None:
|
||||
Pe = abs(component.variables["Wt"])
|
||||
|
||||
if Pe <= 0:
|
||||
raise ValueError("Pe must be positive")
|
||||
|
||||
fit_term = 30.522 * math.log(Pe) - 5.7178
|
||||
if fit_term <= 0:
|
||||
raise ValueError(
|
||||
"Pe is outside the valid logarithmic domain for this "
|
||||
"empirical mass formula"
|
||||
)
|
||||
|
||||
mass = A * math.sqrt(0.5 * math.pi * fit_term)
|
||||
return {
|
||||
"mass": mass,
|
||||
"A": A,
|
||||
"Pe": Pe,
|
||||
"fit_term": fit_term,
|
||||
"formula": "A*sqrt(0.5*pi*(30.522*ln(Pe)-5.7178))",
|
||||
}
|
||||
|
||||
|
||||
def calculate_heater_mass(
|
||||
component,
|
||||
P_heat_mwt=None,
|
||||
mass_flow_rate=None,
|
||||
shielding_mass_ton=2.8,
|
||||
include_shielding=True,
|
||||
**kwargs,
|
||||
):
|
||||
"""Estimate reactor and shielding mass for the heater module.
|
||||
|
||||
Reactor empirical formula from the provided reference:
|
||||
M_reactor = 0.2195 * P_heat + 0.09836
|
||||
|
||||
P_heat is the reactor thermal power in MWt, and masses are in tons.
|
||||
The shielding mass is added as a constant 2.8 ton by default.
|
||||
|
||||
If P_heat_mwt is not supplied, it is estimated from Q_in and
|
||||
mass_flow_rate, assuming Q_in is kJ/kg and mass_flow_rate is kg/s:
|
||||
P_heat_mwt = abs(Q_in) * mass_flow_rate / 1000
|
||||
"""
|
||||
if P_heat_mwt is None:
|
||||
if mass_flow_rate is None:
|
||||
raise ValueError(
|
||||
"Heater mass calculation requires P_heat_mwt, or "
|
||||
"mass_flow_rate to estimate P_heat_mwt from Q_in."
|
||||
)
|
||||
P_heat_mwt = abs(component.variables["Q_in"]) * mass_flow_rate / 1000
|
||||
|
||||
if P_heat_mwt <= 0:
|
||||
raise ValueError("P_heat_mwt must be positive")
|
||||
if shielding_mass_ton < 0:
|
||||
raise ValueError("shielding_mass_ton must be non-negative")
|
||||
|
||||
reactor_mass_ton = 0.2195 * P_heat_mwt + 0.09836
|
||||
shielding_mass = shielding_mass_ton if include_shielding else 0.0
|
||||
total_mass_ton = reactor_mass_ton + shielding_mass
|
||||
|
||||
return {
|
||||
"mass": total_mass_ton,
|
||||
"reactor_mass_ton": reactor_mass_ton,
|
||||
"shielding_mass_ton": shielding_mass,
|
||||
"P_heat_mwt": P_heat_mwt,
|
||||
"include_shielding": include_shielding,
|
||||
"formula": "0.2195*P_heat+0.09836+shielding_mass",
|
||||
}
|
||||
|
||||
|
||||
def calculate_condenser_mass(
|
||||
component,
|
||||
Qc_kw=None,
|
||||
co2_mass_flow_rate=None,
|
||||
coolant_outlet_T=None,
|
||||
water_inlet_T=None,
|
||||
water_mass_flow_rate=None,
|
||||
water_pressure_kpa=101.325,
|
||||
refprop_path="C:/Program Files (x86)/REFPROP 10.0+/REFPROP",
|
||||
emissivity=0.92,
|
||||
surface_temperature=210.15,
|
||||
area_density=6.75,
|
||||
**kwargs,
|
||||
):
|
||||
"""Estimate radiator mass for the condenser module.
|
||||
|
||||
Radiator heat rejection model:
|
||||
Qc = phi * sigma * A_rad * (T**4 - T0**4)
|
||||
M_rad = kappa * A_rad
|
||||
|
||||
The NaK coolant in the reference is represented here by water. If
|
||||
coolant_outlet_T is not supplied, water outlet temperature is evaluated
|
||||
with REFPROP from water_inlet_T, water_mass_flow_rate, and Qc_kw.
|
||||
"""
|
||||
if Qc_kw is None:
|
||||
if co2_mass_flow_rate is None:
|
||||
raise ValueError(
|
||||
"Condenser mass calculation requires Qc_kw, or "
|
||||
"co2_mass_flow_rate to estimate Qc_kw from Q_out."
|
||||
)
|
||||
Qc_kw = abs(component.variables["Q_out"]) * co2_mass_flow_rate
|
||||
|
||||
if Qc_kw <= 0:
|
||||
raise ValueError("Qc_kw must be positive")
|
||||
if emissivity <= 0:
|
||||
raise ValueError("emissivity must be positive")
|
||||
if area_density <= 0:
|
||||
raise ValueError("area_density must be positive")
|
||||
|
||||
if coolant_outlet_T is None:
|
||||
coolant_outlet_T = calculate_water_outlet_temperature(
|
||||
Qc_kw=Qc_kw,
|
||||
water_inlet_T=water_inlet_T,
|
||||
water_mass_flow_rate=water_mass_flow_rate,
|
||||
water_pressure_kpa=water_pressure_kpa,
|
||||
refprop_path=refprop_path,
|
||||
)
|
||||
|
||||
temperature_term = coolant_outlet_T**4 - surface_temperature**4
|
||||
if temperature_term <= 0:
|
||||
raise ValueError(
|
||||
"coolant_outlet_T must be higher than surface_temperature for "
|
||||
"radiative heat rejection"
|
||||
)
|
||||
|
||||
stefan_boltzmann = 5.670374419e-8
|
||||
Qc_w = Qc_kw * 1000
|
||||
area_m2 = Qc_w / (emissivity * stefan_boltzmann * temperature_term)
|
||||
mass_kg = area_density * area_m2
|
||||
|
||||
return {
|
||||
"mass": mass_kg,
|
||||
"radiator_area_m2": area_m2,
|
||||
"Qc_kw": Qc_kw,
|
||||
"coolant_outlet_T": coolant_outlet_T,
|
||||
"surface_temperature": surface_temperature,
|
||||
"emissivity": emissivity,
|
||||
"area_density": area_density,
|
||||
"mass_unit": "kg",
|
||||
"formula": "M_rad=kappa*Qc/(phi*sigma*(T^4-T0^4))",
|
||||
}
|
||||
|
||||
|
||||
def calculate_water_outlet_temperature(
|
||||
Qc_kw,
|
||||
water_inlet_T,
|
||||
water_mass_flow_rate,
|
||||
water_pressure_kpa,
|
||||
refprop_path,
|
||||
):
|
||||
"""Calculate water outlet temperature for the condenser mass model."""
|
||||
import ctREFPROP.ctREFPROP as ct
|
||||
|
||||
if water_inlet_T is None or water_mass_flow_rate is None:
|
||||
raise ValueError(
|
||||
"Provide coolant_outlet_T directly, or provide water_inlet_T "
|
||||
"and water_mass_flow_rate for REFPROP water calculation."
|
||||
)
|
||||
if water_mass_flow_rate <= 0:
|
||||
raise ValueError("water_mass_flow_rate must be positive")
|
||||
|
||||
water = ct.REFPROPFunctionLibrary(refprop_path)
|
||||
water.SETUPdll(1, "WATER.FLD", "HMX.BNC", "DEF")
|
||||
water.SETUPdll(2, "SI", "SI", "DEF")
|
||||
z = [1.0]
|
||||
mw = water.WMOLdll(z)
|
||||
|
||||
inlet = water.TPFLSHdll(water_inlet_T, water_pressure_kpa, z)
|
||||
if inlet.ierr > 0:
|
||||
raise ValueError(f"REFPROP water inlet calculation error: {inlet.ierr}")
|
||||
|
||||
h_in_mass = inlet.h / mw
|
||||
h_out_mass = h_in_mass + Qc_kw / water_mass_flow_rate
|
||||
outlet = water.PHFLSHdll(water_pressure_kpa, h_out_mass * mw, z)
|
||||
if outlet.ierr > 0:
|
||||
raise ValueError(f"REFPROP water outlet calculation error: {outlet.ierr}")
|
||||
|
||||
return outlet.T
|
||||