修正动态管与阀门诊断输出

This commit is contained in:
huojiarong committed 2026-08-18 10:24:29 +00:00
1 parent f725f038b6
commit 53f8601fec
6 files changed
+219 -16

No files matched your search

+104 -1
View File
@@ -1,7 +1,7 @@
from __future__ import annotations
import unittest
from math import log10
from math import log10, sqrt
from app.simulation.components.amesim.flow.pipes import AmesimPnl0002, AmesimPnl0003
from app.simulation.core.medium import IdealGasMedium
@@ -200,6 +200,79 @@ class AmesimPnl0002ComponentTests(unittest.TestCase):
self.assertAlmostEqual(derivative[0], 0.3)
self.assertAlmostEqual(derivative[1], 0.3 * props.h)
def test_result_cm_averages_bare_parameter_for_each_resistance(self) -> None:
pipe = AmesimPnl0002(
"pnl_2",
self.medium,
diam=0.02,
le=2.0,
rr=0.045 / 20.0,
p0=100000.0,
T0=350.0,
)
center = pipe.properties()
pipe.port_1.p = 130000.0
pipe.port_2.p = 80000.0
pipe.update_flow_temperature_references(
{
"port_1": self.medium.specific_enthalpy_at_pressure(
pipe.port_1.p,
250.0,
),
"port_2": self.medium.specific_enthalpy_at_pressure(
pipe.port_2.p,
450.0,
),
}
)
raw_parameters: list[float] = []
bare_parameters: list[float] = []
frictions: list[float] = []
for port_name, port in (
("port_1", pipe.port_1),
("port_2", pipe.port_2),
):
flow = pipe.port_mass_flow(
port.p,
center.p,
center.T,
port_name=port_name,
)
if flow >= 0.0:
upstream_pressure = port.p
upstream_temperature = pipe.medium.temperature_from_pressure_enthalpy(
port.p,
pipe._connected_h[port_name],
)
else:
upstream_pressure = center.p
upstream_temperature = center.T
reynolds = pipe.reynolds_number(flow, upstream_temperature)
friction = pipe.friction_factor(reynolds)
raw = (
abs(flow)
* sqrt(upstream_temperature)
/ (pipe.area * upstream_pressure)
)
flow_coefficient = sqrt(
pipe.diam / (pipe.resistance_length * friction)
)
raw_parameters.append(raw)
bare_parameters.append(raw / flow_coefficient)
frictions.append(friction)
expected = sum(bare_parameters) / 2.0
collapsed = (sum(raw_parameters) / 2.0) / sqrt(
pipe.diam
/ (pipe.resistance_length * (sum(frictions) / 2.0))
)
actual = pipe.component_result_values()["cm"]
self.assertAlmostEqual(actual, expected)
self.assertGreater(abs(actual - collapsed), 1.0e-8)
class AmesimPnl0003ComponentTests(unittest.TestCase):
def setUp(self) -> None:
@@ -389,6 +462,36 @@ class AmesimPnl0003ComponentTests(unittest.TestCase):
self.assertIn("dmctr", values)
self.assertIn("re", values)
def test_result_cm_excludes_center_resistance_flow_coefficient(self) -> None:
pipe = AmesimPnl0003(
"pnl_3",
self.medium,
diam=0.02,
le=0.3,
rr=0.045 / 20.0,
p1_0=10.7e6,
T1_0=263.4,
p2_0=10.68e6,
T2_0=263.42,
)
port_1 = pipe.properties_1()
port_2 = pipe.properties_2()
flow = pipe.resistance_mass_flow()
upstream = port_1 if flow >= 0.0 else port_2
reynolds = pipe.reynolds_number(flow, upstream.T)
friction = pipe.friction_factor(reynolds)
raw_cq_cm = (
abs(flow)
* sqrt(upstream.T)
/ (pipe.area * max(port_1.p, port_2.p))
)
flow_coefficient = sqrt(pipe.diam / (pipe.le * friction))
actual = pipe.component_result_values()["cm"]
self.assertAlmostEqual(actual, raw_cq_cm / flow_coefficient)
self.assertNotAlmostEqual(actual, raw_cq_cm)
if __name__ == "__main__":
unittest.main()