接入test_mql双管路气室与PN3节点

This commit is contained in:
huojiarong committed 2026-07-17 03:39:14 +00:00
1 parent 1193b2dcee
commit c4c1b35dee
5 files changed
+552

No files matched your search

+82
View File
@@ -0,0 +1,82 @@
from __future__ import annotations
from dataclasses import dataclass
from PythonModels.systems.test_mql import COMPONENT_SPECS
@dataclass(frozen=True)
class TestMqlPneumaticNode3Balance:
temperature_k: float
pressure_pa: float
port_1_enthalpy_flow_w: float
port_1_mass_flow_g_s: float
port_1_volume_derivative_l_min: float
port_1_volume_cm3: float
port_2_enthalpy_flow_w: float
port_2_mass_flow_g_s: float
port_2_volume_derivative_l_min: float
port_2_volume_cm3: float
port_3_enthalpy_flow_w: float
port_3_mass_flow_g_s: float
port_3_volume_derivative_l_min: float
port_3_volume_cm3: float
@dataclass(frozen=True)
class TestMqlPneumaticNode3:
"""Exact algebraic contract of AMESim ``PN3NODE2``.
Pressure and temperature are fixed by port 2 and duplicated to ports 1 and
3. Flow and volume signals at port 2 are the sums of ports 1 and 3, matching
the ``EXPRESS2`` equations stored in ``test_mql_.cir``.
"""
alias: str
def balance(
self,
*,
port_2_temperature_k: float,
port_2_pressure_pa: float,
port_1_enthalpy_flow_w: float,
port_1_mass_flow_g_s: float,
port_3_enthalpy_flow_w: float,
port_3_mass_flow_g_s: float,
port_1_volume_derivative_l_min: float = 0.0,
port_1_volume_cm3: float = 0.0,
port_3_volume_derivative_l_min: float = 0.0,
port_3_volume_cm3: float = 0.0,
) -> TestMqlPneumaticNode3Balance:
if port_2_temperature_k <= 0.0:
raise ValueError("port_2_temperature_k must be positive")
if port_2_pressure_pa <= 0.0:
raise ValueError("port_2_pressure_pa must be positive")
return TestMqlPneumaticNode3Balance(
temperature_k=port_2_temperature_k,
pressure_pa=port_2_pressure_pa,
port_1_enthalpy_flow_w=port_1_enthalpy_flow_w,
port_1_mass_flow_g_s=port_1_mass_flow_g_s,
port_1_volume_derivative_l_min=port_1_volume_derivative_l_min,
port_1_volume_cm3=port_1_volume_cm3,
port_2_enthalpy_flow_w=(
port_1_enthalpy_flow_w + port_3_enthalpy_flow_w
),
port_2_mass_flow_g_s=port_1_mass_flow_g_s + port_3_mass_flow_g_s,
port_2_volume_derivative_l_min=(
port_1_volume_derivative_l_min + port_3_volume_derivative_l_min
),
port_2_volume_cm3=port_1_volume_cm3 + port_3_volume_cm3,
port_3_enthalpy_flow_w=port_3_enthalpy_flow_w,
port_3_mass_flow_g_s=port_3_mass_flow_g_s,
port_3_volume_derivative_l_min=port_3_volume_derivative_l_min,
port_3_volume_cm3=port_3_volume_cm3,
)
def build_test_mql_node3_assembly() -> dict[str, TestMqlPneumaticNode3]:
return {
str(spec["alias"]): TestMqlPneumaticNode3(alias=str(spec["alias"]))
for spec in COMPONENT_SPECS
if spec["submodel"] == "PN3NODE2"
}