Files
SystemSimulationApp/tests/test_test_mql_pneumatic.py
T

131 lines
5.9 KiB
Python

from __future__ import annotations
import unittest
from pathlib import Path
from PythonModels.components.amesim_pneumatic import HELIUM_PNEUMATIC_GAS, cm3_to_m3
from PythonModels.reporting.amesim_results import load_test_mql_amesim_results
from PythonModels.systems.test_mql_pneumatic import (
absolute_pressure_from_amesim_bar_parameter,
build_test_mql_pneumatic_assembly,
pressure_from_amesim_bar_parameter,
pressure_to_amesim_gauge_pa,
)
REPO_ROOT = Path(__file__).resolve().parents[1]
TEST_MQL_AME = REPO_ROOT / "AmesimModels" / "test_mql.ame"
class TestMqlPneumaticAssemblyTests(unittest.TestCase):
@classmethod
def setUpClass(cls) -> None:
cls.amesim_results = load_test_mql_amesim_results(TEST_MQL_AME)
def test_assembles_expected_amesim_pneumatic_component_counts(self) -> None:
assembly = build_test_mql_pneumatic_assembly()
self.assertEqual(len(assembly.fixed_chambers), 4)
self.assertEqual(len(assembly.variable_chambers), 8)
self.assertEqual(len(assembly.fixed_orifices), 8)
self.assertEqual(len(assembly.variable_orifices), 8)
self.assertEqual(assembly.component_count, 28)
self.assertIn("pn_general_chamber", assembly.aliases)
self.assertIn("pn_c1_8", assembly.aliases)
self.assertIn("pn_orifice_18", assembly.aliases)
self.assertIn("pn_morifice_11", assembly.aliases)
def test_uses_amesim_pressure_conventions(self) -> None:
assembly = build_test_mql_pneumatic_assembly()
self.assertAlmostEqual(absolute_pressure_from_amesim_bar_parameter(153.0), 15300000.0)
self.assertAlmostEqual(pressure_from_amesim_bar_parameter(153.0), 15198700.0)
self.assertAlmostEqual(pressure_to_amesim_gauge_pa(100000.0), -1300.0)
self.assertAlmostEqual(assembly.fixed_initial_absolute_pressure_pa, 15300000.0)
self.assertAlmostEqual(assembly.fixed_initial_gauge_pressure_pa, 15198700.0)
self.assertAlmostEqual(assembly.variable_initial_absolute_pressure_pa, 100000.0)
self.assertAlmostEqual(assembly.variable_initial_gauge_pressure_pa, -1300.0)
self.assertAlmostEqual(assembly.initial_pressure_pa, 15198700.0)
def test_chamber_parameters_are_resolved_in_si_units(self) -> None:
assembly = build_test_mql_pneumatic_assembly()
fixed_chamber = assembly.fixed_chambers["pn_general_chamber"]
variable_chamber = assembly.variable_chambers["pn_c1_8"]
self.assertAlmostEqual(fixed_chamber.volume, 0.057)
self.assertAlmostEqual(variable_chamber.dead_volume, 0.015)
self.assertAlmostEqual(variable_chamber.volume, 0.015)
self.assertIs(fixed_chamber.gas, HELIUM_PNEUMATIC_GAS)
self.assertIs(variable_chamber.gas, HELIUM_PNEUMATIC_GAS)
self.assertAlmostEqual(fixed_chamber.properties().T, 293.15)
self.assertAlmostEqual(variable_chamber.properties().T, 293.15)
def test_orifice_parameters_are_resolved_in_si_units(self) -> None:
assembly = build_test_mql_pneumatic_assembly()
fixed_orifice = assembly.fixed_orifices["pn_orifice_18"]
variable_orifice = assembly.variable_orifices["pn_morifice_11"]
self.assertAlmostEqual(fixed_orifice.area, 78.5e-6)
self.assertAlmostEqual(fixed_orifice.flow_coefficient, 0.9)
self.assertAlmostEqual(variable_orifice.area, 78.5e-6)
self.assertAlmostEqual(variable_orifice.flow_coefficient, 0.45)
self.assertAlmostEqual(variable_orifice.opening, 0.0)
self.assertEqual(assembly.variable_orifice_control_count, 8)
control = assembly.variable_orifice_controls["pn_morifice_11"]
self.assertEqual(control.step.alias, "step_8")
self.assertAlmostEqual(control.opening_at(0.0), 0.0)
self.assertAlmostEqual(control.opening_at(0.039), 0.0)
self.assertAlmostEqual(control.opening_at(0.04), 1.0)
assembly.set_variable_orifice_openings(0.04)
self.assertAlmostEqual(variable_orifice.opening, 1.0)
def test_chamber_initial_observables_match_amesim_results(self) -> None:
assembly = build_test_mql_pneumatic_assembly()
fixed_chamber = assembly.fixed_chambers["pn_general_chamber"]
variable_chamber = assembly.variable_chambers["pn_c1_8"]
self.assertAlmostEqual(
fixed_chamber.pressure_gauge_pa(),
self.amesim_results.series("press@pn_general_chamber")[0],
delta=1.0e-8,
)
self.assertAlmostEqual(
variable_chamber.pressure_gauge_pa(),
self.amesim_results.series("press@pn_c1_8")[0],
delta=1.0e-8,
)
self.assertAlmostEqual(
variable_chamber.volume_cm3(),
self.amesim_results.series("vol@pn_c1_8")[0],
)
self.assertAlmostEqual(
variable_chamber.gas_mass_g(),
self.amesim_results.series("mgas1@pn_c1_8")[0],
delta=1.0e-4,
)
def test_variable_chamber_volume_matches_piston_volume_observable(self) -> None:
assembly = build_test_mql_pneumatic_assembly()
for chamber_alias, chamber in assembly.variable_chambers.items():
piston_alias = chamber_alias.replace("pn_c1", "pn_brp2")
with self.subTest(alias=chamber_alias):
piston_volume_cm3 = self.amesim_results.series(f"vol1@{piston_alias}")[-1]
chamber.set_external_volume_m3(cm3_to_m3(piston_volume_cm3))
self.assertAlmostEqual(
chamber.volume_cm3(),
self.amesim_results.series(f"vol@{chamber_alias}")[-1],
delta=1.0e-6,
)
def test_assembled_orifice_can_compute_helium_mass_flow(self) -> None:
assembly = build_test_mql_pneumatic_assembly()
fixed_orifice = assembly.fixed_orifices["pn_orifice_18"]
flow = fixed_orifice.mass_flow(15.0e6, 10.0e6, 293.15)
self.assertGreater(flow, 0.0)
if __name__ == "__main__":