merge/model-development-into-main #2
No files matched your search
@@ -3863,6 +3863,7 @@ class TestMqlSystem:
|
||||
self.pnl0003_assembly = self._build_pnl0003_assembly()
|
||||
self.pnl00r_assembly = self._build_pnl00r_assembly()
|
||||
self.node3_assembly = self._build_node3_assembly()
|
||||
self.node4_assembly = self._build_node4_assembly()
|
||||
self.pneumatic_assembly = self._build_pneumatic_assembly()
|
||||
pneumatic_components = self._pneumatic_components_by_alias()
|
||||
for spec in COMPONENT_SPECS:
|
||||
@@ -3912,6 +3913,12 @@ class TestMqlSystem:
|
||||
|
||||
return build_test_mql_node3_assembly()
|
||||
|
||||
@staticmethod
|
||||
def _build_node4_assembly():
|
||||
from PythonModels.systems.test_mql_nodes import build_test_mql_node4_assembly
|
||||
|
||||
return build_test_mql_node4_assembly()
|
||||
|
||||
def _pneumatic_components_by_alias(self) -> dict[str, Component]:
|
||||
return {
|
||||
**self.pneumatic_assembly.fixed_chambers,
|
||||
@@ -3940,6 +3947,10 @@ class TestMqlSystem:
|
||||
def typed_node3_count(self) -> int:
|
||||
return len(self.node3_assembly)
|
||||
|
||||
@property
|
||||
def typed_node4_count(self) -> int:
|
||||
return len(self.node4_assembly)
|
||||
|
||||
def _pnl0003_spec_for_node_port(self, node_alias: str, port_name: str):
|
||||
for spec in self.pnl0003_assembly.specs:
|
||||
if spec.source_component == node_alias and spec.source_port == port_name:
|
||||
|
||||
@@ -74,9 +74,107 @@ class TestMqlPneumaticNode3:
|
||||
)
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class TestMqlPneumaticNode4Balance:
|
||||
temperature_k: float
|
||||
pressure_pa: float
|
||||
port_1_enthalpy_flow_w: float
|
||||
port_1_mass_flow_g_s: float
|
||||
port_1_volume_derivative_l_min: float
|
||||
port_1_volume_cm3: float
|
||||
port_2_enthalpy_flow_w: float
|
||||
port_2_mass_flow_g_s: float
|
||||
port_2_volume_derivative_l_min: float
|
||||
port_2_volume_cm3: float
|
||||
port_3_enthalpy_flow_w: float
|
||||
port_3_mass_flow_g_s: float
|
||||
port_3_volume_derivative_l_min: float
|
||||
port_3_volume_cm3: float
|
||||
port_4_enthalpy_flow_w: float
|
||||
port_4_mass_flow_g_s: float
|
||||
port_4_volume_derivative_l_min: float
|
||||
port_4_volume_cm3: float
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class TestMqlPneumaticNode4:
|
||||
"""Exact algebraic contract of AMESim ``P4NODE2``.
|
||||
|
||||
Pressure and temperature are fixed by port 2 and duplicated to ports 1, 3,
|
||||
and 4. Flow and volume signals at port 2 are the sums of ports 1, 3, and
|
||||
4, matching the saved AMESim variables for ``pnnode4_*`` instances.
|
||||
"""
|
||||
|
||||
alias: str
|
||||
|
||||
def balance(
|
||||
self,
|
||||
*,
|
||||
port_2_temperature_k: float,
|
||||
port_2_pressure_pa: float,
|
||||
port_1_enthalpy_flow_w: float,
|
||||
port_1_mass_flow_g_s: float,
|
||||
port_3_enthalpy_flow_w: float,
|
||||
port_3_mass_flow_g_s: float,
|
||||
port_4_enthalpy_flow_w: float,
|
||||
port_4_mass_flow_g_s: float,
|
||||
port_1_volume_derivative_l_min: float = 0.0,
|
||||
port_1_volume_cm3: float = 0.0,
|
||||
port_3_volume_derivative_l_min: float = 0.0,
|
||||
port_3_volume_cm3: float = 0.0,
|
||||
port_4_volume_derivative_l_min: float = 0.0,
|
||||
port_4_volume_cm3: float = 0.0,
|
||||
) -> TestMqlPneumaticNode4Balance:
|
||||
if port_2_temperature_k <= 0.0:
|
||||
raise ValueError("port_2_temperature_k must be positive")
|
||||
if port_2_pressure_pa <= 0.0:
|
||||
raise ValueError("port_2_pressure_pa must be positive")
|
||||
return TestMqlPneumaticNode4Balance(
|
||||
temperature_k=port_2_temperature_k,
|
||||
pressure_pa=port_2_pressure_pa,
|
||||
port_1_enthalpy_flow_w=port_1_enthalpy_flow_w,
|
||||
port_1_mass_flow_g_s=port_1_mass_flow_g_s,
|
||||
port_1_volume_derivative_l_min=port_1_volume_derivative_l_min,
|
||||
port_1_volume_cm3=port_1_volume_cm3,
|
||||
port_2_enthalpy_flow_w=(
|
||||
port_1_enthalpy_flow_w
|
||||
+ port_3_enthalpy_flow_w
|
||||
+ port_4_enthalpy_flow_w
|
||||
),
|
||||
port_2_mass_flow_g_s=(
|
||||
port_1_mass_flow_g_s
|
||||
+ port_3_mass_flow_g_s
|
||||
+ port_4_mass_flow_g_s
|
||||
),
|
||||
port_2_volume_derivative_l_min=(
|
||||
port_1_volume_derivative_l_min
|
||||
+ port_3_volume_derivative_l_min
|
||||
+ port_4_volume_derivative_l_min
|
||||
),
|
||||
port_2_volume_cm3=(
|
||||
port_1_volume_cm3 + port_3_volume_cm3 + port_4_volume_cm3
|
||||
),
|
||||
port_3_enthalpy_flow_w=port_3_enthalpy_flow_w,
|
||||
port_3_mass_flow_g_s=port_3_mass_flow_g_s,
|
||||
port_3_volume_derivative_l_min=port_3_volume_derivative_l_min,
|
||||
port_3_volume_cm3=port_3_volume_cm3,
|
||||
port_4_enthalpy_flow_w=port_4_enthalpy_flow_w,
|
||||
port_4_mass_flow_g_s=port_4_mass_flow_g_s,
|
||||
port_4_volume_derivative_l_min=port_4_volume_derivative_l_min,
|
||||
port_4_volume_cm3=port_4_volume_cm3,
|
||||
)
|
||||
|
||||
|
||||
def build_test_mql_node3_assembly() -> dict[str, TestMqlPneumaticNode3]:
|
||||
return {
|
||||
str(spec["alias"]): TestMqlPneumaticNode3(alias=str(spec["alias"]))
|
||||
for spec in COMPONENT_SPECS
|
||||
if spec["submodel"] == "PN3NODE2"
|
||||
}
|
||||
|
||||
def build_test_mql_node4_assembly() -> dict[str, TestMqlPneumaticNode4]:
|
||||
return {
|
||||
str(spec["alias"]): TestMqlPneumaticNode4(alias=str(spec["alias"]))
|
||||
for spec in COMPONENT_SPECS
|
||||
if spec["submodel"] == "P4NODE2"
|
||||
}
|
||||
@@ -5,7 +5,10 @@ from pathlib import Path
|
||||
|
||||
from PythonModels.reporting.amesim_results import load_test_mql_amesim_results
|
||||
from PythonModels.systems.test_mql import TestMqlSystem
|
||||
from PythonModels.systems.test_mql_nodes import build_test_mql_node3_assembly
|
||||
from PythonModels.systems.test_mql_nodes import (
|
||||
build_test_mql_node3_assembly,
|
||||
build_test_mql_node4_assembly,
|
||||
)
|
||||
|
||||
|
||||
REPO_ROOT = Path(__file__).resolve().parents[1]
|
||||
@@ -83,5 +86,88 @@ class TestMqlPneumaticNode3Tests(unittest.TestCase):
|
||||
)
|
||||
|
||||
|
||||
class TestMqlPneumaticNode4Tests(unittest.TestCase):
|
||||
@classmethod
|
||||
def setUpClass(cls) -> None:
|
||||
cls.nodes = build_test_mql_node4_assembly()
|
||||
cls.results = load_test_mql_amesim_results(TEST_MQL_AME)
|
||||
|
||||
def test_builds_all_eight_p4node2_instances(self) -> None:
|
||||
self.assertEqual(len(self.nodes), 8)
|
||||
self.assertIn("pnnode4_17", self.nodes)
|
||||
system = TestMqlSystem()
|
||||
self.assertEqual(system.typed_node4_count, 8)
|
||||
self.assertEqual(system.node4_assembly["pnnode4_17"].alias, "pnnode4_17")
|
||||
|
||||
def test_port_two_flow_is_exact_sum_of_ports_one_three_and_four(self) -> None:
|
||||
balance = self.nodes["pnnode4_17"].balance(
|
||||
port_2_temperature_k=281.0,
|
||||
port_2_pressure_pa=4.4e6,
|
||||
port_1_enthalpy_flow_w=2.0,
|
||||
port_1_mass_flow_g_s=3.0,
|
||||
port_3_enthalpy_flow_w=-0.5,
|
||||
port_3_mass_flow_g_s=-1.0,
|
||||
port_4_enthalpy_flow_w=4.0,
|
||||
port_4_mass_flow_g_s=5.0,
|
||||
port_1_volume_derivative_l_min=4.0,
|
||||
port_1_volume_cm3=5.0,
|
||||
port_3_volume_derivative_l_min=-1.0,
|
||||
port_3_volume_cm3=6.0,
|
||||
port_4_volume_derivative_l_min=2.0,
|
||||
port_4_volume_cm3=7.0,
|
||||
)
|
||||
|
||||
self.assertEqual(balance.temperature_k, 281.0)
|
||||
self.assertEqual(balance.pressure_pa, 4.4e6)
|
||||
self.assertEqual(balance.port_2_enthalpy_flow_w, 5.5)
|
||||
self.assertEqual(balance.port_2_mass_flow_g_s, 7.0)
|
||||
self.assertEqual(balance.port_2_volume_derivative_l_min, 5.0)
|
||||
self.assertEqual(balance.port_2_volume_cm3, 18.0)
|
||||
|
||||
def test_pnnode4_17_baseline_matches_adjacent_flow_sum(self) -> None:
|
||||
index = 500
|
||||
balance = self.nodes["pnnode4_17"].balance(
|
||||
port_2_temperature_k=self.results.series("temp1@pnnode4_17")[index],
|
||||
port_2_pressure_pa=(
|
||||
self.results.series("press1@pnnode4_17")[index] + 101_300.0
|
||||
),
|
||||
port_1_enthalpy_flow_w=self.results.series("dh1@pneumatic_86")[index],
|
||||
port_1_mass_flow_g_s=self.results.series("dm1@pneumatic_86")[index],
|
||||
port_3_enthalpy_flow_w=self.results.series("dh2@pneumatic_83")[index],
|
||||
port_3_mass_flow_g_s=self.results.series("dm2@pneumatic_83")[index],
|
||||
port_4_enthalpy_flow_w=self.results.series("dh2@pn_morifice_9")[index],
|
||||
port_4_mass_flow_g_s=self.results.series("dm2@pn_morifice_9")[index],
|
||||
)
|
||||
|
||||
self.assertAlmostEqual(
|
||||
balance.port_2_mass_flow_g_s,
|
||||
self.results.series("dm2@pnnode4_17")[index],
|
||||
)
|
||||
self.assertAlmostEqual(
|
||||
balance.port_2_enthalpy_flow_w,
|
||||
self.results.series("dh2@pnnode4_17")[index],
|
||||
)
|
||||
self.assertEqual(self.results.series("vol2@pnnode4_17")[index], 0.0)
|
||||
self.assertEqual(self.results.series("dvol2@pnnode4_17")[index], 0.0)
|
||||
self.assertAlmostEqual(
|
||||
self.results.series("press1@pnnode4_17")[index],
|
||||
self.results.series("p2@pneumatic_68")[index],
|
||||
)
|
||||
|
||||
def test_rejects_nonphysical_primary_pressure_or_temperature(self) -> None:
|
||||
node = self.nodes["pnnode4_17"]
|
||||
with self.assertRaises(ValueError):
|
||||
node.balance(
|
||||
port_2_temperature_k=0.0,
|
||||
port_2_pressure_pa=1.0e5,
|
||||
port_1_enthalpy_flow_w=0.0,
|
||||
port_1_mass_flow_g_s=0.0,
|
||||
port_3_enthalpy_flow_w=0.0,
|
||||
port_3_mass_flow_g_s=0.0,
|
||||
port_4_enthalpy_flow_w=0.0,
|
||||
port_4_mass_flow_g_s=0.0,
|
||||
)
|
||||
|
||||
|
||||
if __name__ == "__main__":
|
||||
unittest.main()
|
||||
Reference in new issue